Technical Specifications
So you're a bit of a tech-nut? Good for you! Here be a full & comprehensive break-down of our core infrastructure, no holds barred...
CloudHeartland Core Infrastructure
- CloudHeartland chooses Citrix XenServer as its virtual server Hypervisor and HP Proliant for its physical server infrastructure.
- Servers are connected to HP storage comprising multiple disks configured in RAID1+0 via redundant controllers and multiple Fibre Channel connections.
- TrendMicro Antivirus is deployed across all servers.
- Virtual servers are automatically and continuously load balanced across physical servers. If a production physical server host fails, virtual servers continue to run without any impact.
- Redundant power supplies are installed in servers and storage with power supplies split across “A” and “B” power feeds.
^ top
Data Centre Features
- Single-storey data centre with concrete perimeter walls.
- Client Conference Room with Presentation screen and white-board.
- 24x7x365 Video surveillance and remote monitoring throughout.
- On site computer service room with hot swap spares for same day repairs.
- Security mesh, reinforced door frames, walls and ceilings at all entry points.
- Man-trap entry, monitored proximity card access and personnel control.
- Dual path 24/7/365 monitored alarm and glass break.
- Premier HP 1 meter deep lockable 42U racks.
^ top
Power Infrastructure
- Power security: "A" and "B" power feeds per rack.
- Different distribution boards and UPS units.
- Our generator can power the entire data centre indefinitely.
- Monthly routine systems testing and maintenance
- 2x 16A or 2x 32A feeds per rack.
- Secured, standby 500KvA 2506 Perkins diesel generator, housed inside the facility (on 24/7 SLA for repairs & refueling).
- Three Secured, in-line Riello UPS power conditioners, isolation transformers that limits peak voltage (amplitude) and the edge-speed (frequency) of electrical transients between the mains power and the racks PDU's power.
^ top
Connectivity and Bandwidth
- Carrier Neutral data centre.
- Juniper 10GbE wire-speed core network access.
- Fibre carriers all have multiple redundant bundles of fibre entering the data centre from different ducts: Vector Communications and Telecom or TelstraCLEAR.
- Strict cabling standards have been uniformly utilised using T568B configuration.
- 24/7/365 network monitoring by our Network Operations Center (NOC).
- Domestic peering for high speed traffic delivery within New Zealand.
- HD can provide carrier grade or flat rate Internet connectivity via Ethernet.
- Diverse carriers, you can connect to any or all of these peers from inside our data centre: HD, Fastcom, FX, WxC, APE, WIX, Telecom, Vector Communications, Telstra, Maxnet, Oddessey andVocus.
^ top
Air Conditioning
- We have 3 fully redundant and intelligent HVAC CRAC units with POD based temperature monitoring and flow control with micro particle air filtration.
- The data centre operates using strict thermal guidelines for data processing environments.
- We can support Blade systems, maximum of 4 enclosures per rack.
- Temperature is 21 °C and a humidity of 49% with a maximum dew point of 15°C.